Skip to content

Busway systems

A busway for every application

LVA Busway

01of 4 · LVA

Power for every level.

Buildings, retail, hospitals and indoor industry.

View product: LVA

Compare and download

Specifications and datasheets

  • LVA Busway (illustrative render)Most widely used

    LVA Busway

    Aluminum busway for low-voltage feeders and plug-in distribution in commercial, industrial and high-rise buildings.

    Rated current
    250 – 5000 A
    Conductor
    Aluminum
    Protection
    IP54 – IP66
    Plug-in outlets
    Every 570 mm
  • GM Busway (illustrative render)IP68

    GM Busway

    Cast-resin busway for wet, corrosive or buried runs, where the system must stay sealed against water and dust.

    Rated current
    250 – 6300 A
    Rated voltage
    400 – 690 V
    Protection
    IP68
    Ambient temp.
    −50 to +55 °C
  • Data Pro Busway (illustrative render)Built for data centers

    Data Pro Busway

    Overhead track busway for data halls and white space: add or move rack feeds without rewiring.

    Rated current
    160 – 1000 A
    Tap-off breakers
    16 – 125 A
    Protection
    IP42
    Monitoring
    Optional module
  • GM-Z MV Busway

    Cast-resin medium-voltage busway for generator and transformer connections on large power projects. Engineered per project.

    Rated voltage
    3.6 – 40.5 kV
    Rated current
    800 – 6300 A
    Protection
    IP68 · IK10 (12 kV)
    Standard
    IEC 62271-1

Ideal for

Where each system is used

LVA BuswayMost widely used

Our versatile solution for indoor commercial and industrial power distribution.

  • High-rise buildingsVertical risers through buildings over ten floors
  • Shopping mallsHorizontal runs through corridors and service areas
  • HospitalsDistribution to hospital facilities and technical rooms
  • Indoor industryManufacturing and automated production plants
  • Corporate buildingsMulti-floor office distribution and electrical risers
GM BuswayIP68

Cast-resin, fully encapsulated busway for demanding environments (IP68).

  • Chemical plantsCorrosive industrial environments
  • Hydroelectric plantsHumid generation facilities
  • Naval industry and portsSaltwater, marine infrastructure and shipbuilding
  • Underground or submergedFully encapsulated runs below ground or in water
  • Outdoor, wet and corrosive areasSealed IP68 runs exposed to weather and humidity
Data Pro BuswayBuilt for data centers

High-density, organized power distribution for critical technology infrastructure.

  • Data centersOverhead distribution above server racks
  • Telecommunications centersNetwork and communication infrastructure
  • Specialized laboratoriesTechnical and scientific facilities
  • AI and high-performance computingHigh-density computing infrastructure
  • Cryptocurrency miningHigh-density equipment with large power and cooling demands
GM-Z MV BuswayMedium voltage

Specialized medium-voltage distribution for technically demanding projects.

  • Hydroelectric generationMV links associated with generating equipment
  • Coastal generationDistribution in demanding marine environments
  • Underground MV distributionEncapsulated busway installed below ground
  • Naval and port infrastructureMV routes in coastal and maritime facilities
  • Nuclear power plantsMV generator and transformer links in generation facilities

Illustrative images

Side by side

Compare busway systems

Headline values from each datasheet. Open a product page for full specifications.

LVA BuswayMost widely used
Voltage
Low voltage, up to 690 V
Conductor
Aluminum
Rated current
250 – 5000 A
Protection
IP54 – IP66

Best for: Default choice for low-voltage feeders and risers

System components

Everything the run needs

Each system ships with matching fittings so the run keeps its rating from source to load.

  • Feeders and plug-in lengthsStraight lengths with or without plug-in outlets along the run.
  • Elbows, tees and offsetsFlatwise and edgewise elbows, tees and offsets to follow the route.
  • Joints and wall flangesBolted or elastic joints and flanges for walls and floor slabs.
  • Source connectionsFlanged ends and cable boxes for transformers and switchboards.
  • Tap-off unitsBreaker or fuse tap-offs to feed loads along the busway.
  • MonitoringOptional temperature and power monitoring, depending on the system.

Have a project? Tell us what you need.

Send drawings, a spec or just the basics.

Specialist product · GM-Z

Are you looking for medium-voltage busway?

GM-Z is a cast-resin busway built for medium-voltage power: typically the link between generators, transformers and switchgear in power plants and large industrial sites.

It is engineered and quoted project by project. Most commercial and industrial buildings need a low-voltage system such as LVA or GM instead.

Read the GM-Z overview